F00: Fault: Flow temperature sensor

F01: Fault: Return temperature sensor

F10: Short circuit: Flow temperature sensor

F11: Short circuit: Return temperature sensor

F12: Short circuit: Cylinder temperature sensor

F13: Short circuit: Temperature sensor for the domestic hot water cylinder

F20: afety shutdown: Overheating temperature urereached

F22: Safety shutdown: Water deficiency in the boiler

F23: Safety shutdown: Temperature spread too great (NTC1/NTC2)

F24: Safety shutdown: Temperature rise too fast

F25: Safety shutdown: Flue gas temperature too high

F27: Afety shutdown: Fault in flame detection

F28: Fault: Ignition unsuccessful when starting up

F29: Fault: Reignition following flame loss unsuccessful

F32: Fan speed outside of the tolerance values

F49: eBUS fault: Voltage too low

F61: Fault: Fuel valve actuation. The gas valve assembly cannot be actuated

F62: Fault: Gas valve switch-off control

F63: Fault: EEPROM

F64: Fault: Electronics / sensor / analogue-to digital converter

F65: Fault: Electronics temperature too high

F67: Value sent back by ASIC is incorrect (flame signal)

F68: Fault: Unstable flame (analogue input)

F70: Invalid product code (DSN)

F71: Fault: Flow/return temperature sensor

F72: Fault: Deviation in the water pressure sensor/return temperature sensor

F73: Fault: Water pressure sensor short circuited

F74: Fault: Water pressure sensor not connected

F75: Fault: Pump/water deficiency

F76: The safety cut-out in the primary heat exchanger is defective

F77: Fault: Condensate or smoke

F78: Interruption to DHW outlet sensor at external control

F83: Fault: Dry fire

F84: Fault: Flow/return temperature sensor

F85: Fault: Temperature sensor

F87: Fault: Ignition transformer cable

F88: Fault: Gas valve assembly

F89: Fault: Pump

F97: Fault: Main PCB self-test failed

Connection: No communication between the main PCB and the user interface

 

 

 

 

     
Vaillant ecoFIT pure 25, 30 and 35 Installation Manual
     
Vaillant ecoFIT pure 25, 30 and 25 User Manual
     
Vaillant ecoFIT pure Fault Code

 

 

Boiler engineer in Nottingham   Boiler repair in Nottingham   Boiler serving in Nottingham   Gas combi boiler installation in Nottingham   Power flushing central heating in Nottingham   Gas safety certificate in Nottingham   Gas hobs and cooker installation in Nottingham   Emergency plumber in Nottingham
F00 | F01 | F10 | F11 | F12 | F13 | F20 | F22 | F23 | F24 | F25 | F27 | F28 | F29 | F32 | F49 | F61 | F62 | F63 | F64 | F65 | F70 | F71 | F72 | F73 | F74 | F75 | F76 | F77 | F78